Wednesday, February 27, 2013

Sanyo Air Conditioning Units - Insulate in a Home!


Sanyo Air Conditioning Units. Where to Insulate in a Home.



For optimal energy efficiency, your home should be properly insulated from the roof down to its foundation. In addition to insulation, consider moisture and air leakage control in each area of your house. If radon is an issue where you live, you’ll also need to consider radon.



Air Water Heat Pump Price. ATTIC INSULATION.



Loose-fill or batt insulation is typically installed in an attic. Loose-fill insulation is usually less expensive to install than batt insulation, and provides better coverage when installed properly. See more on different types of insulation. Before insulating, seal any air leaks and make roof and other necessary repairs. If it is located in a conditioned part of the house, also remember to insulate and air seal your attic access.


 


Insulate and air seal any knee walls -- vertical walls with attic space directly behind them -- in your home as well. In addition, if you're building a new home or remodeling, make sure any attic decking that provides additional storage space or a platform for a heating and/or cooling unit or hot water tank is raised above the ceiling joists to leave room for adequate insulation. Finally, if you live in a hot or warm climate, consider installing a radiant barrier in your attic to reduce summer heat gain.


Wall Mounted Air Conditioning Unit. DUCT INSULATION.



If the ducts in your home are in unconditioned space, seal and insulate them. If you’re building a new house, place ducts in the conditioned space to avoid the energy losses associated with most duct systems.


Cassette Air Conditioning. CATHEDRAL CEILING INSULATION.





Properly insulating your cathedral ceilings will allow ceiling temperatures to remain closer to room temperatures, providing an even temperature distribution throughout the house. Cathedral ceilings must provide space between the roof deck and home’s ceiling for adequate insulation and ventilation. This can be achieved through the use of truss joists, scissor truss framing, or sufficiently large rafters. For example, cathedral ceilings built with 2x12 rafters have space for standard 10-inch batts (R-30) and ventilation.


 


Foil-faced batt insulation is often used in cathedral ceilings because it provides the permeability rating often required for use in ceilings without attics. A vent baffle should be installed between the insulation and the roof decking to maintain the ventilation channel.


 


Consider using high-density R-30 batts, which are as thick as R-25 batts, but fit into 2x10 framing. You can also add rigid foam insulation under the rafters, which adds R-value and eliminates thermal bridging through wood rafters. However, rigid foam insulation must be covered with a fire-rated material when used on the interior of a building. Half-inch drywall is usually sufficient, but check with local building officials before installing.



No comments: