Midea 48000 BTU 17.4 SEER Ducted in Minisplitwarehouse.com

Midea 48000 BTU 17.4 SEER Ducted in Minisplitwarehouse.com The most popular types of air conditioners are ducted and split system. Get Midea 48000 BTU 17.4 SEER Ducted Mini Split Heat Pump AC. Price: $3,139.99 ex. tax. Call us 877-770-3548 or visit our website.


*This Package Includes:*(1) Outdoor Unit 48,000Btu (DLCLR)AH48AAKPRE-CHARGED with R410a Freon

DLCLR Features Include:

Heats
 & Cools (-22°F/-13°F)Basepan Heater (Built in)
Golden Hydrophilic Fins7yr Compressor 5yr Parts Warranty
Click the Buttons below for detailed product info:
Product Brochure Compressor Specifications

*(1) 
Indoor Unit 48,000Btu DLFLDAH48XAK(Built in Condensate Pump)
DLFLD Slim Ducted
Specifications
AHRI Certificate


Copper Lines & Wires Not Included!Please see the drop down boxes above to add copper lines & wires.Requires 2 Sets of wires, 1-(3 wire) for Power Indoor to Outdoor & 1-(3 wire) For Signal
 


Mini Split Reviews | Compare toHome Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits
Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.

Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
  • DLFLCA Cassette
  • DLFLDA Ducted
  • DLFLFA Console
Color: Clay
DLCLRA Outdoor Unit
Heat Pump
Size48
Outdoor ModelDLCLRAH48AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Refrigerant
TypeR410A
Chargelbs (kg)9.26 (4.2)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)217.4 (98.6)
AirflowCFM4,500
Sound PressuredB(A)62.5
DLFLCAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER16.8
EER9.5
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (17° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11.0
COP (47° F)W/W3.6
COP (47° F)W/W2.62
COP (5° F)W/W1.84
DLFLDAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.4
EER9.2
Heating Rated Capacity (47° F)Btu/h49,500
Heating Rated Capacity (17° F)Btu/h33,400
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF10.3
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84
DLFLFAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.8
EER9.3
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Vertical or Horizontal Installation
    Designed for maximum installation flexibility with the built-in secondary drain pan which allows the unit to be mounted vertically for either a floor or ceiling-concealed installation, depending on existing conditions for sizes 36 & 48 only.
  • Built-In Codensate Lift Pump
    Supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.


FEATURES

  • Available in 208/230V
  • Up to 17.4 SEER and up to 12.0 HSPF when paired with DLCLRA outdoor unit.
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Vertical (sizes 36 & 48) or horizontal installation
  • Up to 0.8 in WG
  • Rear or bottom return (sizes 36 & 48)
  • Constant CFM operation on sizes 36 & 48 only
  • Built-in condensate lift pump
  • Follow Me (senses temperature at optional handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 38.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
Compatible With:
  • DLCLRA Outdoor Unit Single Zone

Color: None
DLFSDA Ducted
Heat Pump
System
Size48
Indoor ModelDLFLDAH48XAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA.3.2
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Indoor
Unit Widthin (mm)47.24 (1200)
Unit Heightin (mm)11.81 (300)
Unit Depthin (mm)34.41 (874)
Net Weightlbs (kg)119.71 (54.3)
Number of Fan Speeds3
Airflow (lowest to highest)CFM720/1030/1230
Sound Pressure (lowest to highest)dB(A)46/49.5/50.5
Max. Static Pressurein (WG)0.64
Field Drain Pipe Size O.D.in (mm)1 (25.4)

Ducted Mini Split Heat Pump in Minisplitwarehouse.com


Ducted Mini Split Heat Pump in Minisplitwarehouse.com Ducted Heat Pumps provide discreet air conditioned comfort. Get Midea 60000 Btu 18 SEER Ducted Mini Split Heat Pump AC. Price: $3,969.99 ex. tax. Call us 877-770-3548 or visit our website.


This Package Includes:

*(1) Commercial Grade Outdoor UnitDLCLRAH58AAK

Heats and Cools (-22f/-13f)
*Built-in Basepan Heater
*Condenser High Temp Protection
*Refrigerant Leak Detection
*Quiet Operation (62.5dB)
*Gold Coated Fins
*213ft Max Piping Length
*7 Yr Compressor / 5 Yr Parts Warranty

Submittal Sheet  Brochure
User Manual  Install Manual

*(1) Commercial Grade Indoor Unit
DLFLDAH58XAK

*Gold Coated Fins
*Wired Programmable Thermostat with Ducted Indoor

(Click The Images Below for More Information on the Indoor Units)

DLFLD Product Sheet




Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
  • DLFLDA Ducted
  • DLFLFA Console
Color: Clay
DLCLRA Outdoor Unit
Heat Pump
Size58
Outdoor ModelDLCLRAH58AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)3/4 (19)
Refrigerant
TypeR410A
Chargelbs (kg)10.19 (4.62)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)225.09 (102.1)
AirflowCFM4,415
Sound PressuredB(A)64.0
DLFLDAH58XAK
ENERGY STAR®NO
Cooling System Tons4.8
Cooling Rated CapacityBtu/h58,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER10.0
Heating Rated Capacity (47° F)Btu/h62,000
Heating Rated Capacity (17° F)Btu/h37,600
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF9.0
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.91
DLFLFAH58XAK
ENERGY STAR®NO
Cooling System Tons4.5
Cooling Rated CapacityBtu/h54,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER9.8
Heating Rated Capacity (47° F)Btu/h60,000
Heating Rated Capacity (17° F)Btu/h39,000
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF10.5
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Vertical or Horizontal Installation
    Designed for maximum installation flexibility with the built-in secondary drain pan which allows the unit to be mounted vertically for either a floor or ceiling-concealed installation, depending on existing conditions for sizes 36 & 48 only.
  • Built-In Codensate Lift Pump
    Supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.


FEATURES

  • Available in 208/230V
  • Up to 18.0 SEER and up to 12.0 HSPF when paired with DLCLRA outdoor unit.
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Vertical (sizes 36 & 48) or horizontal installation
  • Up to 0.8 in WG
  • Rear or bottom return (sizes 36 & 48)
  • Constant CFM operation on sizes 36 & 48 only
  • Built-in condensate lift pump
  • Follow Me (senses temperature at optional handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 38.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
Compatible With:
  • DLCLRA Outdoor Unit Single Zone

Color: None
DLFSDA Ducted
Heat Pump
System
Size58
Indoor ModelDLFLDAH58XAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA.3.65
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)3/4 (19)
Indoor
Unit Widthin (mm)55.12 (1400)
Unit Heightin (mm)17.32 (440)
Unit Depthin (mm)33.78 (858)
Net Weightlbs (kg)163 (74)
Number of Fan Speeds3
Airflow (lowest to highest)CFM1260/1710/2150
Sound Pressure (lowest to highest)dB(A)51/54/57
Max. Static Pressurein (WG)0.80
Field Drain Pipe Size O.D.in (mm)1 (25.4)