Midea 4 Zone 21 SEER in Minisplitwarehouse.com Our multi zone ductless experts are here to help you purchase a system at the best price possible. Get Midea 4 Zone 21 SEER Ductless Mini Split Hyper Heat Pump AC. Price: $2,880.99 ex. tax. Call us 877-770-3548 or visit our website.

*This Midea 4 Zone Mini Split Package Includes:*(1) 4 Zone Outdoor Unit 36,000Btu (21.2 SEER)

DLCMRA Features Include:

Heats
 & Cools (-22F/-13F)Basepan Heater (Built in)
Gold Coated Coils7yr Compressor 5yr Parts WarrantySpecifications Brochure AHRI
Allowed Indoor Combinations

*
(4) Indoor Units 9000Btu Wall Mount (DLFEH)



DLFEH Features Include:

Convenient Filter Removal∼ Remove filter from top of unit, no need to open front cover.
Improved Servicability∼ Full Access to terminal connections and fan after lifting front cover.
8 Modes∼ Cool, Heat, Dry, Fan, Auto, TURBO, Sleep, Heating Setback(46F)
4 Fan SpeedsFollow Me∼ Uses remote control as the sensor
Gold Coated Coils∼Remote Controls∼Specifications  
Brochure

Warranty Card
____________________________________________________________Installation Kits are not included, please see the dropdown boxes above for those options.
_______________________________________________________________________

With This Package you are able to
 "UPGRADE" The Outdoor unit to a Larger one and the default 9000btu Wall Mount DLFEH to larger sizes, different series and types of indoor units like:
Advantage Series Wall MountMax Series Wall Mount,
Ceiling Cassette's , Slim Hidden Ducted, 
Console/Universal Mount
Click the Images Below for more information

DLFSH Specifications
Brochure
DLFPH Specifications
Brochure
DLFSC Specifications
Brochure
DLFSD Specifications
Brochure
DLFSF Specifications
Brochure
DLFSF Specifications
Brochure

Outdoor KEY FEATURES

  • Space Saving Installation
    Up to five indoor units can be connected to a single outdoor unit, reducing the number of outdoor units required. All indoor units can be individually controlled and do not need to be installed at the same time.
  • Multiple Indoor Unit Styles
    Flexibility on the options of indoor unit styles to fit any application or need.


FEATURES

  • Available in 208/230V
  • Connect 1 ~ 4, multiple style indoor units
  • Built-in basepan heater
  • Quiet outdoor operation, as low as 62 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Cooling operating range -13°~122° F (-25°~50° C)
  • Heating operating range -22°~86° F (-30°~30° C)
Compatible With:
  • DLFPHA High Wall
  • DLFSHA High Wall
  • DLFEHA High Wall
  • DLFSCA Cassette
  • DLFSDA Ducted
  • DLFSFA Console
Color: Clay
DLCMRA Outdoor Unit
Heat Pump
Size36
Outdoor ModelDLCMRAH36DAK
Max Number of Zones4
Performance Non-Ducted
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,090~41,470
SEER21.4
EER10.5
Heating Rated Capacity (47° F)Btu/h36,000
Heating Maximum Capacity (5° F)Btu/h26,200
Heating Cap. Range Min - MaxBtu/h6,350~41,950
HSPF10.2
COP (47° F)W/W3.7
COP (5° F)W/W2.7
Performance Combination Ducted and Non-Ducted
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,060~39,990
SEER19.7
EER10.3
Heating Rated Capacity (47° F)Btu/h36,000
Heating Maximum Capacity (5° F)Btu/h27,300
Heating Cap. Range Min - MaxBtu/h6,275~42,305
HSPF10.0
COP (47° F)W/W3.5
COP (5° F)W/W2.6
Performance Ducted
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,030~38,510
SEER17.9
EER10.0
Heating Rated Capacity (47° F)Btu/h36,000
Heating Maximum Capacity (5° F)Btu/h28,400
Heating Cap. Range Min - MaxBtu/h6,200~42,660
HSPF9.7
COP (47° F)W/W3.2
COP (5° F)W/W2.5
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13~122 (-25~50)
Heating Outdoor DB Min - Max° F (° C)-22~86 (-30~30)
Piping
Total Piping Lengthft (m)263 (80)
Piping to furthest FCUft (m)115 (35)
Drop (OD above ID)ft (m)49 (15)
Lift (OD below ID)ft (m)49 (15)
Pipe Connection Size - Liquidin (mm)1/4*4 (6.35*4)
Pipe Connection Size - Suctionin (mm)1/2 *1+ 3/8*3 (12.7*1+9.52*3)
Refrigerant
TypeR410A
Chargelbs (kg)6.61 (3.0)
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA30
MOCP - Fuse RatingA.45
Outdoor
Unit Widthin (mm)41.22 (1047)
Unit Heightin (mm)31.88 (810)
Unit Depthin (mm)17.91 (455)
Net Weightlbs (kg)156.5 (71)
AirflowCFM2,130
Sound PressuredB(A)62
2 Zone
Combinations
3 Zone
Combinations
4 Zone
Combinations
9+189+9+99+9+9+9
12+189+9+129+9+9+12
18+189+9+189+9+9+18
9+12+129+9+12+12
9+12+189+9+12+18
9+18+189+12+12+12
12+12+1212+12+12+12
12+12+18
12+18+18
= Hyper Heating down to -22° F



Larger 48000btu Compressor will allow more BTU at Low temps.