Midea 48000 BTU 16.8 SEER in Minisplitwarehouse.com Ceiling cassette mini split systems are designed for homes without duct systems. They're recessed into the ceiling to provide a modern look. Get Midea 48000 BTU 16.8 SEER Commercial Ceiling Cassette Mini Split Hyper Heat Pump AC. Price: $3,219.99 ex. tax


*This Package Includes:*(1) Outdoor Unit 48,000Btu (DLCLR)AH48AAK

DLCLR Features Include:

Heats
 & Cools (-22°F/-13°F)Basepan Heater (Built in)
Golden Hydrophilic Fins7yr Compressor 5yr Parts Warranty
Click the Buttons below for detailed product info:
Product BrochureCompressor Specifications

*(1)
 Indoor Unit 48,000Btu DLFLCAH48XAK(with Grill KSALG0201AAA) + (Built In Condensate Pump)
DLFLC Ceiling Cassette
Specifications
AHRI Certificate


Copper Lines & Wires Not Included!Please see the drop down boxes above to add copper lines & wires.Requires 2 Sets of wires, 1-(set) for Power Indoor to Outdoor & 1-(set 18AWG) For Signal(Copper Line & Wire Dropdown box bove includes power wire, you will still need the 18AWG signal wire)
 


Mini Split Reviews | Compare toHome Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits
Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.

Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
  • DLFLCA Cassette
  • DLFLDA Ducted
  • DLFLFA Console
Color: Clay
DLCLRA Outdoor Unit
Heat Pump
Size48
Outdoor ModelDLCLRAH48AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Refrigerant
TypeR410A
Chargelbs (kg)9.26 (4.2)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)217.4 (98.6)
AirflowCFM4,500
Sound PressuredB(A)62.5
DLFLCAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER16.8
EER9.5
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (17° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11.0
COP (47° F)W/W3.6
COP (47° F)W/W2.62
COP (5° F)W/W1.84
DLFLDAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.4
EER9.2
Heating Rated Capacity (47° F)Btu/h49,500
Heating Rated Capacity (17° F)Btu/h33,400
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF10.3
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84
DLFLFAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.8
EER9.3
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Built-in Condensate Lift pump
    The cassette is supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.
  • 360° Air Flow Panel
    With the 360° air flow panel, air is distributed to every corner of the room.


FEATURES

  • Available in 208/230V
  • Up to 16.8 SEER and 11.0 HSPF when paired with DLCLRA outdoor unit
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Auto-restart function
  • Louver control (fixed or swing)
  • Three fan speeds
  • Outside air intake
  • Built-in condensate lift pump
  • Follow Me (senses temperature at handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 49 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Grille/ceiling panel 3 x 3 sizes 24 to 48 KSALG0201AAA
Compatible With:
  • DLCLRA Outdoor Unit Single Zone

Color: White
DLFLCA Cassette
Heat Pump
System
Size48
Indoor ModelDLFLCAH48XAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA.1.6
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Indoor
Body Unit Widthin (mm)33.07 (840)
Body Unit Heightin (mm)11.3 (287)
Body Unit Depthin (mm)33.07 (840)
Body Net Weightlbs (kg)63.27 (28.7)
Grille Unit Widthin (mm)37.4 (950)
Grille Unit Heightin (mm)2.17 (55)
Grille Unit Depthin (mm)37.4 (950)
Grille Net Weightlbs (kg)11.02 (5)
Number of Fan Speeds3
Airflow (lowest to highest)CFM853/1030/1177
Sound Pressure (lowest to highest)dB(A)49/52/55
Air Throw Dataft (m)30 (9)
Moisture RemovalPint/h (L/h)13.5 (6.39)
Field Drain Pipe Size O.D.in (mm)1 (25.4)