Tuesday, September 29, 2020

3 Zone 20 SEER Hyper Heat Pump AC in Minisplitwarehouse.com


 3 Zone 20 SEER Hyper Heat Pump AC in Minisplitwarehouse.com Our multi zone ductless experts are here to help you purchase a system at the best price possible. Get Midea 3 Zone 20 SEER Ductless Mini Split Hyper Heat Pump AC. Price: $2,138.99 ex. tax. Call us 877-770-3548 or visit our website.

LINK:

https://www.minisplitwarehouse.com/category/3-zones

*This Midea 3 Zone Mini Split Package Includes:

*(1) 3 Zone Outdoor Unit 27,000Btu (20.4 SEER
)

DLCMRA Features Include:

Heats
 & Cools (-22F/-13F)Basepan Heater (Built in)
Gold Coated Coils7yr Compressor 5yr Parts Warranty
Specifications Brochure AHRI
Allowed Indoor Combinations

*
(3) Indoor Units 9000Btu Wall Mount (DLFEH)



DLFEH Features Include:



Convenient Filter Removal∼ Remove filter from top of unit, no need to open front cover.
Improved Servicability∼ Full Access to terminal connections and fan after lifting front cover.
8 Modes∼ Cool, Heat, Dry, Fan, Auto, TURBO, Sleep, Heating Setback(46F)
4 Fan SpeedsFollow Me∼ Uses remote control as the sensor
Gold Coated Coils∼Remote Controls∼
Specifications  
Brochure

Warranty Card
____________________________________________________________
Installation Kits are not included, please see the dropdown boxes above for those options.
_______________________________________________________________________

With This Package you are able to
 "UPGRADE" 
The Outdoor unit to a Larger one and t
he default 9000btu Wall Mount DLFEH to larger sizes, 
different series and types of indoor units like:
Advantage Series Wall MountMax Series Wall Mount,
Ceiling Cassette's , Slim Hidden Ducted, 
Console/Universal Mount

Click the Images Below for more information

DLFSH Specifications
Brochure
DLFPH Specifications
Brochure
DLFSC Specifications
Brochure
DLFSD Specifications
Brochure
DLFSF Specifications
Brochure
DLFSF Specifications
Brochure
____________________________________________________________________



Outdoor KEY FEATURES

  • Space Saving Installation
    Up to five indoor units can be connected to a single outdoor unit, reducing the number of outdoor units required. All indoor units can be individually controlled and do not need to be installed at the same time.
  • Multiple Indoor Unit Styles
    Flexibility on the options of indoor unit styles to fit any application or need.


FEATURES

  • Available in 208/230V
  • Connect 1 ~ 3, multiple style indoor units
  • Built-in basepan heater
  • Quiet outdoor operation, as low as 62 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Cooling operating range -13°~122° F (-25°~50° C)
  • Heating operating range -22°~86° F (-30°~30° C)

Compatible With:

  • DLFPHA High Wall
  • DLFSHA High Wall
  • DLFEHA High Wall
  • DLFSCA Cassette
  • DLFSDA Ducted
  • DLFSFA Console

Color: Clay


DLCMRA Outdoor Unit
Heat Pump
Size27
Outdoor ModelDLCMRAH27CAK
Max Number of Zones3
Performance Non-Ducted
ENERGY STAR®NO
Cooling System Tons2.3
Cooling Rated CapacityBtu/h27,000
Cooling Cap. Range Min - MaxBtu/h7,880~33,510
SEER20.4
EER11.5
Heating Rated Capacity (47° F)Btu/h27,000
Heating Maximum Capacity (5° F)Btu/h22,700
Heating Cap. Range Min - MaxBtu/h6,010~36,180
HSPF10.8
COP (47° F)W/W4.0
COP (5° F)W/W3.4
Performance Combination Ducted and Non-Ducted
ENERGY STAR®NO
Cooling System Tons2.3
Cooling Rated CapacityBtu/h27,000
Cooling Cap. Range Min - MaxBtu/h7,765~31,955
SEER19.5
EER11.3
Heating Rated Capacity (47° F)Btu/h27,000
Heating Maximum Capacity (5° F)Btu/h21,850
Heating Cap. Range Min - MaxBtu/h5,980~36,190
HSPF9.9
COP (47° F)W/W3.8
COP (5° F)W/W3.0
Performance Ducted
ENERGY STAR®NO
Cooling System Tons2.3
Cooling Rated CapacityBtu/h27,000
Cooling Cap. Range Min - MaxBtu/h7,650~30,400
SEER18.5
EER11.0
Heating Rated Capacity (47° F)Btu/h27,000
Heating Maximum Capacity (5° F)Btu/h21,000
Heating Cap. Range Min - MaxBtu/h5,950~36,200
HSPF9.0
COP (47° F)W/W3.5
COP (5° F)W/W2.7
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13~122 (-25~50)
Heating Outdoor DB Min - Max° F (° C)-22~86 (-30~30)
Piping
Total Piping Lengthft (m)197 (60)
Piping to furthest FCUft (m)98 (30)
Drop (OD above ID)ft (m)49 (15)
Lift (OD below ID)ft (m)49 (15)
Pipe Connection Size - Liquidin (mm)1/4*3 (6.35*3)
Pipe Connection Size - Suctionin (mm)3/8*3 (9.52*3)
Refrigerant
TypeR410A
Chargelbs (kg)6.17(2.8)
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA25
MOCP - Fuse RatingA.35
Outdoor
Unit Widthin (mm)41.22 (1047)
Unit Heightin (mm)31.88 (810)
Unit Depthin (mm)17.91 (455)
Net Weightlbs (kg)149.9 (68)
AirflowCFM2,130
Sound PressuredB(A)63

2 Zone
Combinations
3 Zone
Combinations
9+99+9+9←Wall Mounts Only
←for 3-zone Hyper
9+129+9+12
9+189+9+18
12+129+12+12
12+189+12+18
12+12+12
= Hyper Heating down to -22° F



                                  Larger 36,000btu Compressor will allow more BTU at Low temps.

                                                                     See The Picture Below:

                                              Upgraded Compressor Specs