3 Zone 20 SEER Hyper Heat Pump AC in Minisplitwarehouse.com Our multi zone ductless experts are here to help you purchase a system at the best price possible. Get Midea 3 Zone 20 SEER Ductless Mini Split Hyper Heat Pump AC. Price: $2,138.99 ex. tax. Call us 877-770-3548 or visit our website.
LINK:
https://www.minisplitwarehouse.com/category/3-zones
*This Midea 3 Zone Mini Split Package Includes:
*(1) 3 Zone Outdoor Unit 27,000Btu (20.4 SEER)
DLCMRA Features Include:
∼Heats & Cools (-22F/-13F)∼Basepan Heater (Built in)∼
*(1) 3 Zone Outdoor Unit 27,000Btu (20.4 SEER)
DLCMRA Features Include:
∼Heats & Cools (-22F/-13F)∼Basepan Heater (Built in)∼
∼Gold Coated Coils∼7yr Compressor 5yr Parts Warranty∼
Specifications Brochure AHRI
Allowed Indoor Combinations
*(3) Indoor Units 9000Btu Wall Mount (DLFEH)
DLFEH Features Include:
∼Convenient Filter Removal∼ Remove filter from top of unit, no need to open front cover.
∼Improved Servicability∼ Full Access to terminal connections and fan after lifting front cover.
∼8 Modes∼ Cool, Heat, Dry, Fan, Auto, TURBO, Sleep, Heating Setback(46F)
∼4 Fan Speeds∼Follow Me∼ Uses remote control as the sensor
∼Gold Coated Coils∼Remote Controls∼
Specifications
Brochure
Warranty Card
____________________________________________________________
Installation Kits are not included, please see the dropdown boxes above for those options.
_______________________________________________________________________
With This Package you are able to "UPGRADE"
The Outdoor unit to a Larger one and the default 9000btu Wall Mount DLFEH to larger sizes,
different series and types of indoor units like:
Advantage Series Wall Mount, Max Series Wall Mount,
Ceiling Cassette's , Slim Hidden Ducted, Console/Universal Mount
Click the Images Below for more information
Brochure
Brochure
Brochure
Brochure
Brochure
Brochure
____________________________________________________________________
Specifications Brochure AHRI
Allowed Indoor Combinations
*(3) Indoor Units 9000Btu Wall Mount (DLFEH)
DLFEH Features Include:
∼Convenient Filter Removal∼ Remove filter from top of unit, no need to open front cover.
∼Improved Servicability∼ Full Access to terminal connections and fan after lifting front cover.
∼8 Modes∼ Cool, Heat, Dry, Fan, Auto, TURBO, Sleep, Heating Setback(46F)
∼4 Fan Speeds∼Follow Me∼ Uses remote control as the sensor
∼Gold Coated Coils∼Remote Controls∼
Specifications
Brochure
Warranty Card
____________________________________________________________
Installation Kits are not included, please see the dropdown boxes above for those options.
_______________________________________________________________________
With This Package you are able to "UPGRADE"
The Outdoor unit to a Larger one and the default 9000btu Wall Mount DLFEH to larger sizes,
different series and types of indoor units like:
Advantage Series Wall Mount, Max Series Wall Mount,
Ceiling Cassette's , Slim Hidden Ducted, Console/Universal Mount
Click the Images Below for more information
Brochure
Brochure
Brochure
Brochure
Brochure
Brochure
____________________________________________________________________
Outdoor KEY FEATURES
- Space Saving Installation
Up to five indoor units can be connected to a single outdoor unit, reducing the number of outdoor units required. All indoor units can be individually controlled and do not need to be installed at the same time. - Multiple Indoor Unit Styles
Flexibility on the options of indoor unit styles to fit any application or need.
FEATURES
- Available in 208/230V
- Connect 1 ~ 3, multiple style indoor units
- Built-in basepan heater
- Quiet outdoor operation, as low as 62 dB(A)
- Aluminum Golden Hydrophilic pre-coated fins
- Cooling operating range -13°~122° F (-25°~50° C)
- Heating operating range -22°~86° F (-30°~30° C)
Compatible With:
- DLFPHA High Wall
- DLFSHA High Wall
- DLFEHA High Wall
- DLFSCA Cassette
- DLFSDA Ducted
- DLFSFA Console
Color: Clay
DLCMRA Outdoor Unit | ||
Heat Pump | ||
Size | 27 | |
Outdoor Model | DLCMRAH27CAK | |
Max Number of Zones | 3 | |
Performance Non-Ducted | ||
ENERGY STAR® | NO | |
Cooling System Tons | 2.3 | |
Cooling Rated Capacity | Btu/h | 27,000 |
Cooling Cap. Range Min - Max | Btu/h | 7,880~33,510 |
SEER | 20.4 | |
EER | 11.5 | |
Heating Rated Capacity (47° F) | Btu/h | 27,000 |
Heating Maximum Capacity (5° F) | Btu/h | 22,700 |
Heating Cap. Range Min - Max | Btu/h | 6,010~36,180 |
HSPF | 10.8 | |
COP (47° F) | W/W | 4.0 |
COP (5° F) | W/W | 3.4 |
Performance Combination Ducted and Non-Ducted | ||
ENERGY STAR® | NO | |
Cooling System Tons | 2.3 | |
Cooling Rated Capacity | Btu/h | 27,000 |
Cooling Cap. Range Min - Max | Btu/h | 7,765~31,955 |
SEER | 19.5 | |
EER | 11.3 | |
Heating Rated Capacity (47° F) | Btu/h | 27,000 |
Heating Maximum Capacity (5° F) | Btu/h | 21,850 |
Heating Cap. Range Min - Max | Btu/h | 5,980~36,190 |
HSPF | 9.9 | |
COP (47° F) | W/W | 3.8 |
COP (5° F) | W/W | 3.0 |
Performance Ducted | ||
ENERGY STAR® | NO | |
Cooling System Tons | 2.3 | |
Cooling Rated Capacity | Btu/h | 27,000 |
Cooling Cap. Range Min - Max | Btu/h | 7,650~30,400 |
SEER | 18.5 | |
EER | 11.0 | |
Heating Rated Capacity (47° F) | Btu/h | 27,000 |
Heating Maximum Capacity (5° F) | Btu/h | 21,000 |
Heating Cap. Range Min - Max | Btu/h | 5,950~36,200 |
HSPF | 9.0 | |
COP (47° F) | W/W | 3.5 |
COP (5° F) | W/W | 2.7 |
Operating Range | ||
Cooling Outdoor DB Min - Max | ° F (° C) | -13~122 (-25~50) |
Heating Outdoor DB Min - Max | ° F (° C) | -22~86 (-30~30) |
Piping | ||
Total Piping Length | ft (m) | 197 (60) |
Piping to furthest FCU | ft (m) | 98 (30) |
Drop (OD above ID) | ft (m) | 49 (15) |
Lift (OD below ID) | ft (m) | 49 (15) |
Pipe Connection Size - Liquid | in (mm) | 1/4*3 (6.35*3) |
Pipe Connection Size - Suction | in (mm) | 3/8*3 (9.52*3) |
Refrigerant | ||
Type | R410A | |
Charge | lbs (kg) | 6.17(2.8) |
Electrical | ||
Voltage-Phase-Cycle | V-Ph-Hz | 208/230-1-60 |
Power Supply | Indoor unit powered from outdoor unit | |
MCA | A | 25 |
MOCP - Fuse Rating | A. | 35 |
Outdoor | ||
Unit Width | in (mm) | 41.22 (1047) |
Unit Height | in (mm) | 31.88 (810) |
Unit Depth | in (mm) | 17.91 (455) |
Net Weight | lbs (kg) | 149.9 (68) |
Airflow | CFM | 2,130 |
Sound Pressure | dB(A) | 63 |
2 Zone Combinations | 3 Zone Combinations | |
---|---|---|
9+9 | 9+9+9 | ←Wall Mounts Only ←for 3-zone Hyper |
9+12 | 9+9+12 | |
9+18 | 9+9+18 | |
12+12 | 9+12+12 | |
12+18 | 9+12+18 | |
12+12+12 | ||
= Hyper Heating down to -22° F |
Larger 36,000btu Compressor will allow more BTU at Low temps.
No comments: