Monday, September 21, 2020

Floor Ceiling Mini Split in Minisplitwarehouse.com


 Floor Ceiling Mini Split in Minisplitwarehouse.com We can help you find exactly what you're looking for. Get Midea 48000 BTU 17.8 SEER Commercial Floor Ceiling Mini Split Hyper Heat Pump AC. Price: $3,179.99 ex. tax. Call us 877-770-3548 or visit our website.


*This Package Includes:

*(1) Outdoor Unit 48,000Btu (DLCLR
)AH48AAK


DLCLR Features Include:

Heats
 & Cools (-22°F/-13°F)Basepan Heater (Built in)
Golden Hydrophilic Fins7yr Compressor 5yr Parts Warranty
Click the Buttons below for detailed product info:

Product Brochure Compressor Specifications

*(1) 
Indoor Unit 48,000Btu DLFLFAH48XAK
(NO Condensate Pump)

DLFLF Console
Specifications
AHRI Certificate


Copper Lines & Wires Not Included!
Please see the drop down boxes above to add copper lines & wires.
Requires 2 Sets of wires, 1-(set) for Power Indoor to Outdoor & 1-(set 18AWG) For Signal
(Copper Line & Wire Dropdown box bove includes power wire, you will still need the 18AWG signal wire)
 


Mini Split Reviews | Compare toHome Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits

Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.

Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)

Compatible With:

  • DLFLCA Cassette
  • DLFLDA Ducted
  • DLFLFA Console

Color: Clay


DLCLRA Outdoor Unit
Heat Pump
Size48
Outdoor ModelDLCLRAH48AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Refrigerant
TypeR410A
Chargelbs (kg)9.26 (4.2)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)217.4 (98.6)
AirflowCFM4,500
Sound PressuredB(A)62.5
DLFLCAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER16.8
EER9.5
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (17° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11.0
COP (47° F)W/W3.6
COP (47° F)W/W2.62
COP (5° F)W/W1.84
DLFLDAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.4
EER9.2
Heating Rated Capacity (47° F)Btu/h49,500
Heating Rated Capacity (17° F)Btu/h33,400
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF10.3
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84
DLFLFAH48XAK
ENERGY STAR®NO
Cooling System Tons4.0
Cooling Rated CapacityBtu/h48,000
Cooling Cap. Range Min - MaxBtu/h9,000~50,000
SEER17.8
EER9.3
Heating Rated Capacity (47° F)Btu/h50,000
Heating Rated Capacity (17° F)Btu/h35,000
Heating Maximum Capacity (5° F)Btu/h34,000
Heating Cap. Range Min - MaxBtu/h10,000~55,000
HSPF11
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Outside Air Intake
    Outside air can be brought into the room through the connection available on the indoor unit which helps meet the ventilation air requirements.
  • Flexible installation
    Ability to be installed on the floor or ceiling depending on the application.


FEATURES

  • Available in 208/230V
  • Up to 17.8 SEER and 11.0 HSPF when paired with DLCLRA outdoor unit
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Auto-restart function
  • Capable to be mounted on floor or ceiling
  • Louver control (fixed or swing)
  • Three fan speeds
  • Air discharge from top and bottom (size 12 only)
  • Follow Me (senses temperature at handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 43 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins

Compatible With:

  • DLCLRA Outdoor Unit Single Zone


Color: White

DLFLFA Console
Heat Pump
System
Size48
Indoor ModelDLFLFAH48XAK
Electrical
Voltage-Phase-CycleV-PhHz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCA0.85
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Indoor
Unit Widthin (mm)64.96 (1650)
Unit Heightin (mm)9.25 (235)
Unit Depthin (mm)26.57 (675)
Net Weightlbs (kg)83.78 (38)
Number of Fan Speeds3
Airflow (lowest to highest)CFM1000/1120/1350
Sound Pressure (lowest to highest)dB(A)52/54/57
Air Throw Dataft (m)39(12)
Field Drain Pipe Size O.D.in (mm)1 (25.4)