Monday, December 7, 2020

Ducted Mini Split Hyper Heat Pump in Minisplitwarehouse.com


Ducted Mini Split Hyper Heat Pump in Minisplitwarehouse.com Ducted Systems look very discreet and have been designed with flexibility in mind, which is extremely helpful when designing a system for your home. Get Midea 36000 BTU 16.5 SEER Commercial Ducted Mini Split Hyper Heat Pump. Price: $2,509.99 ex. tax. Call us 877-770-3548.


LINK:

https://www.minisplitwarehouse.com/category/slim-ducted

*This Package Includes:

*(1) Indoor Unit : (DLFLD)AH36XAK

DLFLD 
Features Include:
˜Built-In Codensate Lift Pump˜ Supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.
˜Vertical or Horizontal Installation˜ Designed for maximum installation flexibility with the built-in secondary drain pan which allows the unit to be mounted vertically for either a floor or ceiling-concealed installation depending on existing conditions.
˜6 Modes˜ Cool, Heat, Dry, Fan, Auto, Heating Setback(46f)
˜Rear or bottom return˜
˜Follow Me˜ Uses remote control as the sensor.
˜Carbon Filter˜Gold Coated Coils˜

*(1) Wired Programmable Thermostat (with ducted only)

*(1) Outdoor Unit: (DLCLR)AH36AAK

DLCLR Features Include:

Heats
 & Cools (-22°F/-13°F)Basepan Heater (Built in)
Golden Hydrophilic Fins7yr Compressor 5yr Parts Warranty
Click the Buttons below for detailed product info:

Product Brochure Compressor Specifications

(Click For More Info/Specs):



Mini Split Reviews | Compare toHome Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits

Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.

Indoor KEY FEATURES

  • Vertical or Horizontal Installation
    Designed for maximum installation flexibility with the built-in secondary drain pan which allows the unit to be mounted vertically for either a floor or ceiling-concealed installation, depending on existing conditions for sizes 36 & 48 only.
  • Built-In Codensate Lift Pump
    Supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.


FEATURES

  • Available in 208/230V
  • Up to 16.5 SEER and up to 12.0 HSPF when paired with DLCLRA outdoor unit.
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Vertical (sizes 36 & 48) or horizontal installation
  • Up to 0.8 in WG
  • Rear or bottom return (sizes 36 & 48)
  • Constant CFM operation on sizes 36 & 48 only
  • Built-in condensate lift pump
  • Follow Me (senses temperature at optional handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 38.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins

Compatible With:

  • DLCLRA Outdoor Unit Single Zone



DLFSDA Ducted
Heat Pump
System
Size36
Indoor ModelDLFLDAH36XAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA.2.45
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Indoor
Unit Widthin (mm)53.54 (1360)
Unit Heightin (mm)9.8 (249)
Unit Depthin (mm)30.47 (774)
Net Weightlbs (kg)106.48 (48.3)
Number of Fan Speeds3
Airflow (lowest to highest)CFM700/910/1080
Sound Pressure (lowest to highest)dB(A)38.5/42/45.5
Max. Static Pressurein (WG)0.64
Field Drain Pipe Size O.D.in (mm)1 (25.4)

Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)

Compatible With:

  • DLFLCA Cassette
  • DLFLDA Ducted
  • DLFLFA Console

Color: Clay


DLCLRA Outdoor Unit
Heat Pump
Size36
Outdoor ModelDLCLRAH36AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA30
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Refrigerant
TypeR410A
Chargelbs (kg)6.72 (3.05)
Outdoor
Unit Widthin (mm)37.24 (946)
Unit Heightin (mm)31.89 (810)
Unit Depthin (mm)16.14 (410)
Net Weightlbs (kg)148.59 (67.4)
AirflowCFM2,130
Sound PressuredB(A)63.0
DLFLCAH36XAK
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,500~38,000
SEER17.5
EER9.0
Heating Rated Capacity (47° F)Btu/h38,000
Heating Rated Capacity (17° F)Btu/h25,200
Heating Maximum Capacity (17° F)Btu/h25,300
Heating Cap. Range Min - MaxBtu/h9,500~50,000
HSPF10.5
COP (47° F)W/W3
COP (47° F)W/W2.46
COP (5° F)W/W1.71
DLFLDAH36XAK
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,500~38,000
SEER16.5
EER9
Heating Rated Capacity (47° F)Btu/h40,000
Heating Rated Capacity (17° F)Btu/h27,600
Heating Maximum Capacity (5° F)Btu/h25,300
Heating Cap. Range Min - MaxBtu/h9,500~50,000
HSPF11.5
COP (47° F)W/W3
COP (17° F)W/W2.46
COP (5° F)W/W1.71
DLFLFAH36XAK
ENERGY STAR®NO
Cooling System Tons3.0
Cooling Rated CapacityBtu/h36,000
Cooling Cap. Range Min - MaxBtu/h8,500~38,000
SEER16.0
EER8
Heating Rated Capacity (47° F)Btu/h38,000
Heating Rated Capacity (17° F)Btu/h25,400
Heating Maximum Capacity (5° F)Btu/h25,300
Heating Cap. Range Min - MaxBtu/h9,500~50,000
HSPF10
COP (47° F)W/W3
COP (17° F)W/W2.46
COP (5° F)W/W1.71