Hyper Heat Pump AC in Minisplitwarehouse.com Ductless, mini split-system have numerous potential applications in residential, commercial, and institutional buildings. Get Midea 9000 Btu 40 SEER Ductless Mini Split Hyper Heat Pump AC. Price: $1,629.99 ex. tax. Call us 877-770-3548 or visit our website.


LINK:

https://www.minisplitwarehouse.com/page/special-pricing

MAX SERIES/40 SEER/220V

*This Package Includes: 

*(1) Indoor Unit : (DLFPH)AH09XAK

DLFPH 
Features Include:
˜Relative Humidity Sensor˜ Set the desired relative humidity in 5% increments. 
˜Occupancy Sensor˜ "EYE" can send airflow twords or away from people in the room.
˜9 Modes˜ Cool, Heat, Dry, Fan, Auto, Turbo, Eco, Sleep, Heating Setback(46f) 
˜Fully Modulating Fan Speeds˜Louver Control˜ UP, Down, Left & Right.
˜Follow Me˜ Uses remote control as the sensor. 
˜Carbon Filter˜Gold Coated Coils˜

*(1) Outdoor Unit: (DLCPR)AH09AAK 

DLCPR Features Include
˜Heats & Cools (-22F/-22FBasepan Heater (Built in)˜ 
˜100% Heat @ 0F˜ 100% Cool @-22F˜ 
˜Gold Coated Coils˜7yr Compressor 5yr Parts Warranty˜ 
˜Refrigerant Leak Detection˜Auto Restart˜

Specifications  AHRI Certificate  Service Manual



Indoor KEY FEATURES

  • Relative Humidity Sensor
    Increasing comfort by setting the desired relative humidity in 5% increments in a range of 35%~85%.
  • Occupancy Sensor
    Detects activity in the room and adjusts the horizontal angle of airflow to blow away from people or follow people.


FEATURES

  • Available in 208/230V
  • Relative Humidity Sensor
  • Occupancy Sensor
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Turbo Mode
  • Fully modulating fan speeds
  • Sleep Mode
  • ECO Mode
  • Up-down / right-left louver control (fixed or swing)
  • Follow Me (senses temperature at handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 29 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Up to 40.0 SEER and 14.5 HSPF when paired with DLCPRA outdoor unit

Compatible With:

  • DLCPRA Outdoor Unit Single Zone
  • DLCMRA Outdoor Unit Multi-Zone


Color: White

DLFPHA High Wall
Heat Pump
System
Size9
Indoor ModelDLFPHAH09XAK
Electrical
Voltage-Phase-CycleV-PhHz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCA0.3
Operating Range
Cooling Indoor DB Min - Max° F (° C)62~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)1/4 (6.35)
Pipe Connection Size - Suctionin (mm)3/8 (9.52)
Indoor
Unit Widthin (mm)35.2 (895)
Unit Heightin (mm)11.7 (298)
Unit Depthin (mm)9.8 (248)
Net Weightlbs (kg)37.48 (17)
Number of Fan Speeds4
Airflow (lowest to highest)CFM144/245/295/345
Sound Pressure (lowest to highest)dB(A)29/35.5/41.5/45.6
Air Throw Dataft (m)21.98 (6.7)
Moisture RemovalPint/h (L/h)2.11 (1.0)
Field Drain Pipe Size O.D.in (mm)1 (25.4)

OUTDOOR KEY FEATURES

  • Extra Low Temperature Heating
    For when its cold outside, the heat output for the system is up to 75% of rated capacity down to -22° F (-30° C), making this a primary heat source and eliminating the need for a backup heat source.
  • Stepless Frequency Adjustment
    Precise control of the system maintains stable and constant room temperature while reducing sound level and saving energy.


FEATURES

  • 100% Heating capacity at 0° F (-17° C)
  • 100% Cooling capacity at -22° F (-30° C) without additional kit
  • Up to 75% of Heating capacity at -22° F (-30° C)
  • Available in 208/230V
  • Built-in basepan heater
  • Auto-restart function
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 55 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 98 ft. (30 m.)
  • Cooling operating range
    • -22° ~ 122° F (-30° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-25° ~ 30° C)

Compatible With:

  • DLFPHA High Wall

Color: Clay


DLCPRA Outdoor Unit
Heat Pump
Size9
Outdoor ModelDLFPRAH09AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA13
MOCP - Fuse RatingA.15
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-22°~122° (-30°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)98 (30)
Lift (OD below ID)ft (m)49 (15)
Pipe Connection Size - Liquidin (mm)1/4 (6.35)
Pipe Connection Size - Suctionin (mm)3/8 (9.52)
Refrigerant
TypeR410A
Chargelbs (kg)3.5 (1.58)
Outdoor
Unit Widthin (mm)33.27 (845)
Unit Heightin (mm)27.64 (702)
Unit Depthin (mm)14.29 (363)
Net Weightlbs (kg)107.59 (48.8)
AirflowCFM1,380
Sound PressuredB(A)55.5
DLFPHAH09XAK
ENERGY STAR®YES
Cooling System Tons0.75
Cooling Rated CapacityBtu/h9,000
Cooling Cap. Range Min - MaxBtu/h5,000~17,000
SEER40.0
EER15.0
Heating Rated Capacity (47° F)Btu/h10,000
Heating Rated Capacity (17° F)Btu/h7,200
Heating Maximum Capacity (17° F)Btu/h15,690
Heating Maximum Capacity (5° F)Btu/h13,000
Heating Cap. Range Min - MaxBtu/h6,800~19,000
HSPF14.5
COP (47° F)W/W4.00
COP (17° F)W/W2.78
COP (5° F)W/W2.0