Friday, January 31, 2020

Ducted Mini Split Heat Pump in Minisplitwarehouse.com


Ducted Mini Split Heat Pump in Minisplitwarehouse.com Ducted Heat Pumps provide discreet air conditioned comfort. Get Midea 60000 Btu 18 SEER Ducted Mini Split Heat Pump AC. Price: $3,969.99 ex. tax. Call us 877-770-3548 or visit our website.


This Package Includes:

*(1) Commercial Grade Outdoor UnitDLCLRAH58AAK

Heats and Cools (-22f/-13f)
*Built-in Basepan Heater
*Condenser High Temp Protection
*Refrigerant Leak Detection
*Quiet Operation (62.5dB)
*Gold Coated Fins
*213ft Max Piping Length
*7 Yr Compressor / 5 Yr Parts Warranty

Submittal Sheet  Brochure
User Manual  Install Manual

*(1) Commercial Grade Indoor Unit
DLFLDAH58XAK

*Gold Coated Fins
*Wired Programmable Thermostat with Ducted Indoor

(Click The Images Below for More Information on the Indoor Units)

DLFLD Product Sheet




Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
  • DLFLDA Ducted
  • DLFLFA Console
Color: Clay
DLCLRA Outdoor Unit
Heat Pump
Size58
Outdoor ModelDLCLRAH58AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)3/4 (19)
Refrigerant
TypeR410A
Chargelbs (kg)10.19 (4.62)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)225.09 (102.1)
AirflowCFM4,415
Sound PressuredB(A)64.0
DLFLDAH58XAK
ENERGY STAR®NO
Cooling System Tons4.8
Cooling Rated CapacityBtu/h58,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER10.0
Heating Rated Capacity (47° F)Btu/h62,000
Heating Rated Capacity (17° F)Btu/h37,600
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF9.0
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.91
DLFLFAH58XAK
ENERGY STAR®NO
Cooling System Tons4.5
Cooling Rated CapacityBtu/h54,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER9.8
Heating Rated Capacity (47° F)Btu/h60,000
Heating Rated Capacity (17° F)Btu/h39,000
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF10.5
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Vertical or Horizontal Installation
    Designed for maximum installation flexibility with the built-in secondary drain pan which allows the unit to be mounted vertically for either a floor or ceiling-concealed installation, depending on existing conditions for sizes 36 & 48 only.
  • Built-In Codensate Lift Pump
    Supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit.


FEATURES

  • Available in 208/230V
  • Up to 18.0 SEER and up to 12.0 HSPF when paired with DLCLRA outdoor unit.
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Vertical (sizes 36 & 48) or horizontal installation
  • Up to 0.8 in WG
  • Rear or bottom return (sizes 36 & 48)
  • Constant CFM operation on sizes 36 & 48 only
  • Built-in condensate lift pump
  • Follow Me (senses temperature at optional handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 38.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
Compatible With:
  • DLCLRA Outdoor Unit Single Zone

Color: None
DLFSDA Ducted
Heat Pump
System
Size58
Indoor ModelDLFLDAH58XAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCAA.3.65
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)3/4 (19)
Indoor
Unit Widthin (mm)55.12 (1400)
Unit Heightin (mm)17.32 (440)
Unit Depthin (mm)33.78 (858)
Net Weightlbs (kg)163 (74)
Number of Fan Speeds3
Airflow (lowest to highest)CFM1260/1710/2150
Sound Pressure (lowest to highest)dB(A)51/54/57
Max. Static Pressurein (WG)0.80
Field Drain Pipe Size O.D.in (mm)1 (25.4)

Floor Ceiling Mount Mini Split in Minisplitwarehouse.com


Floor Ceiling Mount Mini Split in Minisplitwarehouse.com Compare prices, Lowest Prices, Top Deals. Get Midea 60000 Btu 18 SEER Floor Ceiling Mount Mini Split Heat Pump AC. Price: $3,799.99 ex. tax. Call us 877-770-3548 or visit our website.


This Package Includes:

*(1) Commercial Grade Outdoor Unit DLCLRAH58AAK

Heats and Cools (-22f/-13f)
*Built-in Basepan Heater
*Condenser High Temp Protection
*Refrigerant Leak Detection
*Quiet Operation (62.5dB)
*Gold Coated Fins
*213ft Max Piping Length
*7 Yr Compressor / 5 Yr Parts Warranty

Submittal Sheet  Brochure
User Manual  Install Manual

*(1) Commercial Grade Indoor Unit DLFLFAH58XAK
(NO Condensate Pump)

*Gold Coated Fins

(Click The Images Below for More Information on the Indoor Units)
DLFLA Product Sheet
Remote Control with Floor/Ceiling Indoor



Outdoor KEY FEATURES

  • Longer Piping Lengths
    Piping flexibility up to a total piping length of 213 ft. (65 m.)
  • Low Ambient Cooling
    With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.


FEATURES

  • Available in 208/230V
  • Built-in basepan heater
  • Condenser high-temperature protection
  • Refrigerant leakage detection
  • Quiet outdoor operation, as low as 62.5 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Piping length 213 ft. (65 m)
  • Cooling operating range
    • -13° ~ 122° F (-25° ~ 50° C)
  • Heating operating range
    • -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
  • DLFLDA Ducted
  • DLFLFA Console
Color: Clay
DLCLRA Outdoor Unit
Heat Pump
Size58
Outdoor ModelDLCLRAH58AAK
Electrical
Voltage-Phase-CycleV-Ph-Hz208/230-1-60
MCAA35
MOCP - Fuse RatingA.50
Operating Range
Cooling Outdoor DB Min - Max° F (° C)-13°~122° (-25°~50°)
Heating Outdoor DB Min - Max° F (° C)-22°~86° (-30°~30°)
Piping
Total Piping Lengthft (m)213 (65)
Lift (OD below ID)ft (m)98 (30)
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)3/4 (19)
Refrigerant
TypeR410A
Chargelbs (kg)10.19 (4.62)
Outdoor
Unit Widthin (mm)37.48 (952)
Unit Heightin (mm)52.48 (1333)
Unit Depthin (mm)16.34 (415)
Net Weightlbs (kg)225.09 (102.1)
AirflowCFM4,415
Sound PressuredB(A)64.0
DLFLDAH58XAK
ENERGY STAR®NO
Cooling System Tons4.8
Cooling Rated CapacityBtu/h58,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER10.0
Heating Rated Capacity (47° F)Btu/h62,000
Heating Rated Capacity (17° F)Btu/h37,600
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF9.0
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.91
DLFLFAH58XAK
ENERGY STAR®NO
Cooling System Tons4.5
Cooling Rated CapacityBtu/h54,000
Cooling Cap. Range Min - MaxBtu/h18,000-58,000
SEER18.0
EER9.8
Heating Rated Capacity (47° F)Btu/h60,000
Heating Rated Capacity (17° F)Btu/h39,000
Heating Maximum Capacity (5° F)Btu/h35,000
Heating Cap. Range Min - MaxBtu/h12,000-63,000
HSPF10.5
COP (47° F)W/W3.6
COP (17° F)W/W2.62
COP (5° F)W/W1.84

Indoor KEY FEATURES

  • Outside Air Intake
    Outside air can be brought into the room through the connection available on the indoor unit which helps meet the ventilation air requirements.
  • Flexible installation
    Ability to be installed on the floor or ceiling depending on the application.


FEATURES

  • Available in 208/230V
  • Up to 18.0 SEER and 11.0 HSPF when paired with DLCLRA outdoor unit
  • Modes: Cool, Heat, Dry, Fan, Auto
  • Auto-restart function
  • Capable to be mounted on floor or ceiling
  • Louver control (fixed or swing)
  • Three fan speeds
  • Air discharge from top and bottom (size 12 only)
  • Follow Me (senses temperature at handheld remote)
  • Heating Setback (46° F Heating Mode)
  • Quiet indoor operation, as low as 43 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
Compatible With:
  • DLCLRA Outdoor Unit Single Zone

Color: White
DLFLFA Console
Heat Pump
System
Size58
Indoor ModelDLFLFAH58XAK
Electrical
Voltage-Phase-CycleV-PhHz208/230-1-60
Power SupplyIndoor unit powered from outdoor unit
MCA1.48
Operating Range
Cooling Indoor DB Min - Max° F (° C)63~90 (17~32)
Heating Indoor DB Min - Max° F (° C)32~86 (0~30)
Piping
Pipe Connection Size - Liquidin (mm)3/8 (9.52)
Pipe Connection Size - Suctionin (mm)5/8 (16)
Indoor
Unit Widthin (mm)64.96 (1650)
Unit Heightin (mm)9.25 (235)
Unit Depthin (mm)26.57 (675)
Net Weightlbs (kg)110 (50)
Number of Fan Speeds3
Airflow (lowest to highest)CFM796/1029/1385
Sound Pressure (lowest to highest)dB(A)46/49/55
Air Throw Dataft (m)39(12)
Field Drain Pipe Size O.D.in (mm)1 (25.4)

Thursday, January 30, 2020

Reactor for Ductless Mini Split Systems in Minisplitwarehouse.com

Reactor for Ductless Mini Split Systems in Minisplitwarehouse.com Learn more about the best accessories for mini split systems. Get Reactor for Ductless Mini Split Systems Transformer. Price: $159.99 ex. tax. Call us 877-770-3548 or visit our website.

Transformer/Reactor for Ductless Systems
Please specify the model number of the unit that this part is for using the dropdown box below. If your model number is NOT listed, choose "Quote Me" and provide the model number at the end of your ordering process (additional info/notes) and provide pictures of the old part.