*This Package Includes:*(1) Outdoor Unit 48,000Btu (DLCLR)AH48AAK
DLCLR Features Include:
∼Heats & Cools (-22°F/-13°F)∼Basepan Heater (Built in)∼
DLCLR Features Include:
∼Heats & Cools (-22°F/-13°F)∼Basepan Heater (Built in)∼
∼Golden Hydrophilic Fins∼7yr Compressor 5yr Parts Warranty∼
Click the Buttons below for detailed product info:
Product BrochureCompressor Specifications
*(1) Indoor Unit 48,000Btu DLFLCAH48XAK(with Grill KSALG0201AAA) + (Built In Condensate Pump)
Copper Lines & Wires Not Included!Please see the drop down boxes above to add copper lines & wires.Requires 2 Sets of wires, 1-(set) for Power Indoor to Outdoor & 1-(set 18AWG) For Signal(Copper Line & Wire Dropdown box bove includes power wire, you will still need the 18AWG signal wire)
Click the Buttons below for detailed product info:
Product BrochureCompressor Specifications
*(1) Indoor Unit 48,000Btu DLFLCAH48XAK(with Grill KSALG0201AAA) + (Built In Condensate Pump)
DLFLC Ceiling Cassette Specifications AHRI Certificate |
Copper Lines & Wires Not Included!Please see the drop down boxes above to add copper lines & wires.Requires 2 Sets of wires, 1-(set) for Power Indoor to Outdoor & 1-(set 18AWG) For Signal(Copper Line & Wire Dropdown box bove includes power wire, you will still need the 18AWG signal wire)
Mini Split Reviews | Compare to: Home Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits
Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.
Outdoor KEY FEATURES
- Longer Piping Lengths
Piping flexibility up to a total piping length of 213 ft. (65 m.) - Low Ambient Cooling
With built-in Low Ambient Kit or special designed PCB, outdoor fan speeds can be changed automatically based on the temperature. The unit can run cooling operation even in low ambient temperatures.
FEATURES
- Available in 208/230V
- Built-in basepan heater
- Condenser high-temperature protection
- Refrigerant leakage detection
- Quiet outdoor operation, as low as 62.5 dB(A)
- Aluminum Golden Hydrophilic pre-coated fins
- Piping length 213 ft. (65 m)
- Cooling operating range
- -13° ~ 122° F (-25° ~ 50° C)
- Heating operating range
- -22° ~ 86° F (-30° ~ 30°C)
- -22° ~ 86° F (-30° ~ 30°C)
Compatible With:
- DLFLCA Cassette
- DLFLDA Ducted
- DLFLFA Console
DLCLRA Outdoor Unit | ||
Heat Pump | ||
Size | 48 | |
Outdoor Model | DLCLRAH48AAK | |
Electrical | ||
Voltage-Phase-Cycle | V-Ph-Hz | 208/230-1-60 |
MCA | A | 35 |
MOCP - Fuse Rating | A. | 50 |
Operating Range | ||
Cooling Outdoor DB Min - Max | ° F (° C) | -13°~122° (-25°~50°) |
Heating Outdoor DB Min - Max | ° F (° C) | -22°~86° (-30°~30°) |
Piping | ||
Total Piping Length | ft (m) | 213 (65) |
Lift (OD below ID) | ft (m) | 98 (30) |
Pipe Connection Size - Liquid | in (mm) | 3/8 (9.52) |
Pipe Connection Size - Suction | in (mm) | 5/8 (16) |
Refrigerant | ||
Type | R410A | |
Charge | lbs (kg) | 9.26 (4.2) |
Outdoor | ||
Unit Width | in (mm) | 37.48 (952) |
Unit Height | in (mm) | 52.48 (1333) |
Unit Depth | in (mm) | 16.34 (415) |
Net Weight | lbs (kg) | 217.4 (98.6) |
Airflow | CFM | 4,500 |
Sound Pressure | dB(A) | 62.5 |
DLFLCAH48XAK | ||
ENERGY STAR® | NO | |
Cooling System Tons | 4.0 | |
Cooling Rated Capacity | Btu/h | 48,000 |
Cooling Cap. Range Min - Max | Btu/h | 9,000~50,000 |
SEER | 16.8 | |
EER | 9.5 | |
Heating Rated Capacity (47° F) | Btu/h | 50,000 |
Heating Rated Capacity (17° F) | Btu/h | 35,000 |
Heating Maximum Capacity (17° F) | Btu/h | 34,000 |
Heating Cap. Range Min - Max | Btu/h | 10,000~55,000 |
HSPF | 11.0 | |
COP (47° F) | W/W | 3.6 |
COP (47° F) | W/W | 2.62 |
COP (5° F) | W/W | 1.84 |
DLFLDAH48XAK | ||
ENERGY STAR® | NO | |
Cooling System Tons | 4.0 | |
Cooling Rated Capacity | Btu/h | 48,000 |
Cooling Cap. Range Min - Max | Btu/h | 9,000~50,000 |
SEER | 17.4 | |
EER | 9.2 | |
Heating Rated Capacity (47° F) | Btu/h | 49,500 |
Heating Rated Capacity (17° F) | Btu/h | 33,400 |
Heating Maximum Capacity (5° F) | Btu/h | 34,000 |
Heating Cap. Range Min - Max | Btu/h | 10,000~55,000 |
HSPF | 10.3 | |
COP (47° F) | W/W | 3.6 |
COP (17° F) | W/W | 2.62 |
COP (5° F) | W/W | 1.84 |
DLFLFAH48XAK | ||
ENERGY STAR® | NO | |
Cooling System Tons | 4.0 | |
Cooling Rated Capacity | Btu/h | 48,000 |
Cooling Cap. Range Min - Max | Btu/h | 9,000~50,000 |
SEER | 17.8 | |
EER | 9.3 | |
Heating Rated Capacity (47° F) | Btu/h | 50,000 |
Heating Rated Capacity (17° F) | Btu/h | 35,000 |
Heating Maximum Capacity (5° F) | Btu/h | 34,000 |
Heating Cap. Range Min - Max | Btu/h | 10,000~55,000 |
HSPF | 11 | |
COP (47° F) | W/W | 3.6 |
COP (17° F) | W/W | 2.62 |
COP (5° F) | W/W | 1.84 |
Indoor KEY FEATURES
- Built-in Condensate Lift pump
The cassette is supplied with a condensate lift pump that is capable of lifting the water 29.5 in. (750 mm.) above the top of the unit. - 360° Air Flow Panel
With the 360° air flow panel, air is distributed to every corner of the room.
FEATURES
- Available in 208/230V
- Up to 16.8 SEER and 11.0 HSPF when paired with DLCLRA outdoor unit
- Modes: Cool, Heat, Dry, Fan, Auto
- Auto-restart function
- Louver control (fixed or swing)
- Three fan speeds
- Outside air intake
- Built-in condensate lift pump
- Follow Me (senses temperature at handheld remote)
- Heating Setback (46° F Heating Mode)
- Quiet indoor operation, as low as 49 dB(A)
- Aluminum Golden Hydrophilic pre-coated fins
- Grille/ceiling panel 3 x 3 sizes 24 to 48 KSALG0201AAA
Compatible With:
- DLCLRA Outdoor Unit Single Zone
Color: White
DLFLCA Cassette | ||
Heat Pump | ||
System | ||
Size | 48 | |
Indoor Model | DLFLCAH48XAK | |
Electrical | ||
Voltage-Phase-Cycle | V-Ph-Hz | 208/230-1-60 |
Power Supply | Indoor unit powered from outdoor unit | |
MCA | A. | 1.6 |
Operating Range | ||
Cooling Indoor DB Min - Max | ° F (° C) | 63~90 (17~32) |
Heating Indoor DB Min - Max | ° F (° C) | 32~86 (0~30) |
Piping | ||
Pipe Connection Size - Liquid | in (mm) | 3/8 (9.52) |
Pipe Connection Size - Suction | in (mm) | 5/8 (16) |
Indoor | ||
Body Unit Width | in (mm) | 33.07 (840) |
Body Unit Height | in (mm) | 11.3 (287) |
Body Unit Depth | in (mm) | 33.07 (840) |
Body Net Weight | lbs (kg) | 63.27 (28.7) |
Grille Unit Width | in (mm) | 37.4 (950) |
Grille Unit Height | in (mm) | 2.17 (55) |
Grille Unit Depth | in (mm) | 37.4 (950) |
Grille Net Weight | lbs (kg) | 11.02 (5) |
Number of Fan Speeds | 3 | |
Airflow (lowest to highest) | CFM | 853/1030/1177 |
Sound Pressure (lowest to highest) | dB(A) | 49/52/55 |
Air Throw Data | ft (m) | 30 (9) |
Moisture Removal | Pint/h (L/h) | 13.5 (6.39) |
Field Drain Pipe Size O.D. | in (mm) | 1 (25.4) |